• Introduce
  • Specifications

◆Fiber amplifier mounting/detaching operation:
1. Mounting
(1)To mount each amplifier to the attached mounting bracket or DIN rail in sequence.

 

 

 

 

 

 

(2)To connect two amplifiers close together by sliding the amplifier bodies.

 

 

 

 

 

 

 

2. Detaching
To detach the amplifiers in sequence by sliding the amplifier bodies. Don't detach two amplifiers at a time.

◆Fiber cables fixing operation:
1. Insert the fiber cables
Open the protective hood and tilt the fiber lock lever to release the lock condition. Referring to the side seal of insertion position, fully insert the fiber cables into the mounting holes until the limit. Pull the fiber lock lever back to lock the cables.

 

 

 

2. Pull out the fiber cables
Open the protective hood and tilt the fiber lock lever to release the lock condition. Pull the fiber cables straight out from the mounting holes.

Notes:Be sure to switch off the power supply when mounting or detaching the amplifier. Notes:To protect the fiber cables from incorrect operation, be sure to tilt the fiber lock lever to release the lock condition before pulling out the fiber cables.
   

Specifications

Output mothod Pre-wired FZ1-N FZ1-P FZ1-NI FZ1-PI
M8 pigtailed type FZ1-ND FZ1-PD - -
Emitting element Red LED 680 nm Infrared LED 850nm
Operating voltage DC12~24V ± 10%
Current Consumption 40mA Max.
Load current 100mA Max.at DC24V
Output Type NPN L.on / D.on PNP L.on / D.on NPN L.on / D.on PNP L.on / D.on
Protection circuit Reversed polarity protection, over-current protection
Response time 0.5 ms Max.
Indicators Output indicator :Red LED, Power indicator:Green LED
Sensitivity adjusrment 20 turns trimmer
Insulation resistance 20M V min. (DC500V)
Voltage Withstandability AC500V 60Hz for 60 Sec.
Operation temperature +10℃~+60℃
Ambient humidity 35%~85% RH
Protection degree IP64
Material ABS
Wiring method FZ1- □ Pre-wired Ø4.2 x 2 M / 3-wires
FZ1-□D M8 pigtailed type / 15cm
Weight FZ1- □ Approx. 65 g
FZ1-□D Approx. 35 g

 